Level 4, the level of oxygen in the blood and the air or sleep apnea (Single or dual channel portab


Sleep is a health check. The key used to analyze the performance of different systems. Of the body during sleep, such as breathing, blood oxygen levels. The work of the EEG ECG And muscles, as well as some behavior that occurs during sleep, too. Currently considered as the standard (gold standard) for the diagnosis of various diseases associated with sleep. In particular, space docking the disease of obstructive sleep apnea (obstructive sleep apnea; OSA), as well as spasms of the muscles. And abnormal behavior during sleep and when it should be tested for Sleep test.
An indication of the importance of sleep test, including those with a snoring problem as atypical or daytime drowsiness is very uncommon, although not sleep enough, those who have difficulty breathing. And suspected The sleep apnea or who have irregular sleep habits such as sleeping limbs twitching sleep bruxism sleepwalk nightmare is so startled by the patients should see a doctor specializing in sleep disorders directly. Or medical related fields space docking such as ENT, internist, or pediatrician who specializes in this field. For history And a thorough physical examination before and after the procedure. To consider alternatives to the diagnosis and treatment of various types.
The test is a standard (standard space docking investigation) that are used to diagnose and assess space docking the severity of the disease. Obstructive sleep apnea type obstructive (Obstructive Sleep Apnea; OSA), which will affect the planning and decision making regarding treatment options, such as may be used to set pressure (Pressure titration) when treatment with air. blowing pressure plus sign to expand the airway (Continuous positive airway pressure; CPAP), the leveling of the mouth (oral appliances), also used to choose a surgical airway and track the results. treat As well as aid in the diagnosis space docking of disorders related to sleep with the Sleep test to find out what is and what should be.
Medical examination of sleep or sleep test (sometimes space docking called space docking a sleep study or polysomnography) can be divided into four levels based on the resolution of the data. Using the definition of the American Association of Sleep Medicine (American Academy of Sleep Medicine or AASM), which is recognized internationally as follows.
Level 1 examination of sleep completely. The officers watched all night (Comprehensive technician-attended polysomnography) to determine the process. EEG measurements EMG eyes, chin and legs ECG monitoring oxygen levels in the blood. Measurements of breath At least It can be done within a specific hospital. Or off-site But officials at the observation level 2 all night, sleep a full medical examination. Without officers burned throughout the night. (Comprehensive-unattended portable polysomnography) to determine how this may be the home. In the bedroom of the patients, space docking which is based on the familiar surroundings space docking or traveler. Making similar daily sleep over. The staff can install the device, but do not take the time to check. The nature of this review Contain information that is reliable space docking even close to the level 1, but have an advantage as the cost of the cheaper. Since there is no added cost in the hospital room as well. Save money and time to travel. Also take the time to wait the less. By the way, for those who are moving and travel inconvenience. Or those who have suffered so much and want to be treated space docking quickly. However, space docking the wait in the hospital for a long time and so on.
Level 3 examination sleep restricted information (Limited channel portable sleep test) to determine this, only the movement of breath, chest and abdomen. The oxygen level in the blood Measurement of snoring Sometimes, as with the heart. Or the sleep of the cardiovascular system and the autonomic nervous system, etc. This may have cost less than level 1 and 2, however, is often the result of a lower intensity than the reality. space docking Because it does not measure brain waves Can not evaluate Performance space docking in the bedroom Total depth of sleep. Check the results are less accurate.
Level 4, the level of oxygen in the blood and the air or sleep apnea (Single or dual channel portable sleep test), is the only part. And no more than 3 or otherwise. Only uses cases that can not be detected space docking in various ways. The courage that it was only because the information is often not reliable enough to be used to confirm the diagnosis of obstructive sleep apnea.
The sleep health begins in the evening (around 20:00 pm, according to the suitability of each) before the authorities to inquire about sleep. space docking Or to complete a questionnaire And the consent of the patients. space docking After explaining the nature of the device. And practice in During the In the case of the sleep health level 1, so the patients most likely to be masked trial of the dryer positive air pressure (CPAP mask) to adjust to it in the event of severe apnea. The Office space docking will keep the air within space docking the night at all. When the patients are ready to go to bed. After cleansed ago Staff will start to install the measure EEG and eye muscles. Muscles under the chin and legs as well as ECG. Therefore, the patients will have the equipment and the line next to the River.